All data is for information only------(Home) | |
---|---|
PRODUCT DATA of AISI 416 |
Material | AISI 416 |
General Information | Martensitic stainless steel |
Precautions | Avoid tempering between 371oC and 593oC , because of reduced resistance to stress corrosion and increased notch sensitivity |
Chemical Composition | Fe-13Cr-0.15S-0.15C |
PHYSICAL PROPERTIES |
---|
Crystal Structure | Face centered cubic (fcc) |
Magnetic Properties | Ferromagnetic |
RELEVANT PROPERTIES FOR USE IN SPACE COMMUNITY |
---|
General Corrosion Status | No specific corrosion protection required |
Corrosion/Thermal | Oxidation resistance is good up to 650C. |
Atmospheric Corrosion | Corrosion resistance is sufficient for most applications, but is inferior to the 300 series stainless steels. This stainless steel type is slightly less corrosion resistant than types 403 and 410 |
Stress Corrosion Status | Moderate Resistance to SCC: Table 2 Remark:Tempering between 371oC and 593oC shall be avoided because corrosion and stress corrosion cracking resistance is lowered. Requires Stress corrosion evaluation form Data Quality: Design Data |
EMF vs SCE | -0.17 V Remark: Measured in 3.5% NaCl solution. Passive condition Data Quality: Design Data |
Bimetallic Corrosion | Can be connected without any restriction to: Cr, Au, Ag, Gun-metal, P-bronzes, Sn-bronzes, Ti+alloys, Ni, Monel, Inconel, Ni/Mo alloys
Can be connected in a non-controlled environment to the above and Cd, austenitic cast iron, Cu, Brasses, Al-bronzes, Si-bronzes, Au, Pt, C, Rh, Sn-Pb alloys, Sn, Pb, 300 series stainless steels Can be connected in a clean room environment to above and Al-Cu alloys Needs specific measures: All others Test:ECSS-Q-ST-70C Rev.1 Table 5.1 Data Quality: Design Data |